PP
PolypropyleneCommodity thermoplastics · Semi-crystalline
A light, economical polymer with excellent chemical resistance and fatigue behaviour — the basis of living hinges and many automotive trims and fluid-handling parts.
- Mechanical strength
- Heat resistance
- Chemical resistance
- Dimensional stability
Full material profile
Key properties
- Very low density
- Excellent chemical resistance
- Good fatigue resistance (living hinges)
- Very low moisture absorption
Typical applications
- Interior trims and covers
- Fluid reservoirs and caps
- Closures with living hinges
- Housings and containers
Heat resistance
Moderate. Retains shape at warm service temperatures, but stiffness falls noticeably as temperature rises; talc- or glass-filled grades improve this.
Chemical resistance
Excellent against many acids, alkalis and aqueous solutions. Can swell in aromatic and chlorinated solvents and is attacked by strong oxidisers.
Moisture absorption
Negligible water absorption; properties are essentially unaffected by humidity.
Dimensional stability
Relatively high and direction-dependent mould shrinkage; flat or long parts need careful design to control warpage.
Advantages
- Low cost and weight
- Easy to mould with short cycles
- Copolymer grades offer good impact performance
Limitations
- Low stiffness unless filled
- Homopolymer can be brittle at low temperature
- Needs UV stabilisation outdoors
- Difficult to bond or paint without surface treatment
Processing considerations
- Generally no pre-drying required
- Design with uniform walls to limit sink and warpage
- Talc or glass fillers alter shrinkage and stiffness
Indicative values — general-purpose grades
- Density, g/cm³
- 0.90 – 0.91
- Melting temp. (Tm)
- ≈ 160 – 168 °C (homopolymer)
- Water absorption
- < 0.1 %
Methods: ISO 1183 (g/cm³); DSC, ISO 11357 — melting temperature (Tm) for semi-crystalline polymers, glass transition (Tg) for amorphous polymers; ISO 62 — saturation in water at 23 °C unless stated; 50 % RH equilibrium where shown. Melting point is not a service temperature — heat-deflection and continuous-use temperatures are lower and grade-specific. Confirm all values on the supplier's datasheet for the exact grade.